AS NZS 3760 PDF

A revised Standard for the safety inspection and testing of electrical equipment has recently been published. ‘The revisions to AS/NZS will. 2. Joint Australian New Zealand Standard. In-service safety inspection and testing of electrical equipment. Superseding AS/NZS A. The AS/NZS is an Australian Standard that oversees the Test and Tag industry in regards to electrical safety of portable appliances.

Author: Grodal Grolar
Country: Bosnia & Herzegovina
Language: English (Spanish)
Genre: Video
Published (Last): 22 February 2014
Pages: 237
PDF File Size: 5.78 Mb
ePub File Size: 6.91 Mb
ISBN: 737-5-27547-624-8
Downloads: 60321
Price: Free* [*Free Regsitration Required]
Uploader: Kitaxe

Regulation You must take all reasonable steps to ensure that electrical work that is required to be undertaken by a licensed or registered electrical worker is undertaken by a worker that meets the relevant licensing or registration requirements. A physical barrier should consist of a non-conductive material such nxs wood or plastic or, alternatively, correctly earthed metal, and be strong enough to withstand any impact from falling objects or loose materials.

In addition to the listed considerations, the assessment should be designed to check compliance with the legislative requirements described above. General Guidance — Use.

AS/NZS 3760

The tools, instruments and bzs used by electrical workers often have special design characteristics, for example many are insulated. In that case, the rest of the required information must be recorded elsewhere and kept for the relevant period of time.

Isolation involves using suitable warning or safety signs as well as locks or other controls to secure the isolation. All workers should be competent in the safe use of their tools and ax including PPE. When testing or fault finding is completed, circuits and equipment must be restored to a safe condition. There are a number of 37600 you should do to manage the risks to health and safety associated with electrical risks at the workplace including: Alternatively, it could be replaced or permanently removed from use.

Electrical equipment commonly used in these types of lower-risk workplaces includes computers, photocopiers, stationery or fixed electrical equipment. All circuit breakers, switches and combined fuse switch units should be locked off to secure the isolation where possible. This includes taking reasonable steps to ensure that the business or 37660 has and uses appropriate resources and processes to eliminate or minimise electrical risks at the workplace. A risk assessment can help determine whether electrical equipment is being used in any of these operating environments at a particular workplace.

Further information about construction work can be found in the Code of Practice: Work health and safety consultation, cooperation and coordination. Tools, instruments and equipment that are poorly maintained, inappropriately used or not fit for purpose can cause injuries, for example: If electricity supply is restored to part of the circuit then safe procedures for restoring electricity supply must be followed.

  GINGER PYE BY ELEANOR ESTES PDF

Persons can be exposed to electrical risks, including risks of electric shock, arcing and explosion, without directly contacting exposed energised nas of electrical equipment. Risk assessment involves considering what could happen if someone is exposed to a hazard consequence and the likelihood of it happening.

AS/NZ Testing Time Interval Table

For example, in an exposed energised high voltage situation, the electricity supply should be isolated and proved de-energised before carrying out a rescue.

You must carry out the electrical work in accordance 376 any safe work method statement that must be prepared for the work. Non-portable RCDs installed at the main switchboard protect nzx wiring connected to the RCD and electrical equipment plugged into the protected circuit. A well-prepared emergency response assists in managing the severity of the injury where an incident has occurred and takes into account the health and safety of those required to respond to the incident. See Figure 5 for examples of locking-off methods incorporating danger tags.

Modifying or repairing existing low-voltage electrical installations. I am satisfied that this code of practice was developed by a process described in section 2 of the Work Health and Safety Act If that is not reasonably practicable you must minimise the risk so far as is reasonably practicable.

A person conducting a business or undertaking has the primary duty under the WHS Act to ensure, so far as is reasonably practicable, that workers and other persons at the workplace are not exposed to electrical risks arising from the business or undertaking. For example, disconnected conductors should be reconnected and left in a safe state, covers replaced, and accessories and equipment properly secured.

Brand-new electrical equipment that has never been put into use i. For guidance on appropriate inspection and testing intervals, seek the advice of a competent person see below.

In some circumstances the most appropriate RCDs may be portable RCDs, particularly to protect mobile workers that do not have fixed places of work and whose PCBU qs have little control over electrical installations where they work. FL Table of contents.

Can the work be undertaken while the electrical equipment is de-energised? This checklist will help you to identify hazards associated with electrical work and develop safe work methods. Examples of metallic personal items include jewellery, body piercings nzz metal spectacle frames. If working on energised equipment, the PPE must be able to protect the user from the maximum prospective energy available at the work site.

  ASTM D5261 PDF

The use of lanyards around wrists, tool holders and restraints such as tool pouches and baskets may be used to address these risks. Additional RCD requirements may be included in local building and electrical safety laws.

Administrative controls involve the use of safe work practices to control the risk, for example the provision of suitable and adequate training, establishing exclusion bzs, use of permits and warning signs. Is a safety observer present? You must ensure, so far as is reasonably practicable, that the information, training and instruction is provided in a way that is readily understandable by any person to whom it is provided.

What Is AS/NZS ? Complete Guide

Are you trained, competent and confident in applying the particular procedures or techniques that are required for the task? For example, safe work method statements should require, so far as is reasonably practicable, that electrical workers position themselves so that: Circuit protection devices may not operate in such circumstances. The barrier must be erected safely.

In these situations, ae should exchange information to find out who is doing what and work together in a cooperative and coordinated way so that all risks are eliminated or minimised so far as is reasonably practicable. Regulation A person conducting a business or undertaking must ensure that electrical work is not carried out on electrical equipment while the equipment is energised, subject to the prescribed exceptions discussed in Section 7 of this Code.

AS/NZS 3760:2010 – Electrical Safety Standard

These operating environments have the nzd to seriously affect the safe operation of electrical equipment. Both ends of the cable should be checked for isolation prior to cutting.

This will reduce the risks associated with poor electrical equipment. Cables must be treated as energised and the procedures for working on energised electrical equipment followed until positive tests can be made that prove the cable is de-energised. Different kinds of safety barriers may be required for different purposes.